Skip to main content Skip to main navigation Skip to site search

Opinion: charging capacity as an asset-level decision

Location, location, power. The old maxim “location, location, location” may be the only dogma in the real estate industry that has never been seriously challenged. Location cannot be built, bought later or negotiated. For a long time I considered the line complete. I now believe its third word needs replacing.

Picture an office building in a prime city-centre location. The anchor tenant wants to renew, on one condition: 40 charging points instead of the current eight, because its fleet goes fully electric next year. The charging energy this requires cannot be delivered during the working day using the available connection capacity. The grid operator quotes a date for reinforcement that lies years away and does not fit the planned fleet transition. A technical question has just turned into a leasing question.

Constrained grids, emptier buildings

A market study from October 2025 sorted the Dutch industrial and logistics market by grid situation. In areas with unrestricted access to electricity, vacancy stood at 3.7 percent in the third quarter. In areas with grid constraints, it stood at 6.9 percent. That is a correlation, not causation, and logistics property is not office property. It is nevertheless the first figure I have come across that places grid connection and lettability side by side.

Charging in Europe shifts into mass-market mode

Since July 2026, applications for new or higher-capacity small grid connections in Dutch congestion areas can end up on waiting lists. In Spain, the distribution system operators’ industry association reported in September 2025 that just over 83 percent of the grid nodes surveyed had no capacity for additional demand. In Germany, the requirements for charging points in existing non-residential buildings with more than 20 parking spaces will be tightened on 1 January 2027.

When I speak of power in what follows, I do not mean the figure on the grid connection agreement. I mean the capacity that is physically, contractually and temporally available, and the charging power that is actually left over once the building’s core activities have been supplied. This quantity is scarce, tied to the site and increasingly decisive for tenants. Those are the qualities that turn a location into a good location.

Everyone has a task, nobody has the plan

Who looks after it? In the conversations I have with owners, the answer is usually much the same. The technical asset manager checks feasibility, and the commercial asset manager runs the business case. Larger investments need an additional approval, and in operation, the property manager and the charging operator come in. Every function has its task. What does not emerge from these tasks on its own is a power strategy for the asset over the next ten years. Anyone who treats charging infrastructure merely as a one-off technical purchase overlooks its consequences for operation, contracts and letting. They surface in the data room at the next sale, and at the next negotiation with a tenant.

Power can be managed

Location is a given. Power is a given too, but it can be shaped, managed and optimised. Alongside the connection capacity, what counts is how the building’s additional energy assets (charging points, rooftop solar and batteries) are integrated with its core demand. The simple version of the question is how much charging energy can be delivered during the working day.

Take an office on a cold morning. The heat pumps are working hard just as employees plug in their cars. A building that manages its power will slow charging for cars parked until the end of the day and prioritise the fleet vehicle that has to leave before lunch. As rooftop solar picks up, its output goes into the vehicles or into the battery. Later, the battery supports the building and the chargers through the next peak, so that less power is drawn from the grid at that moment. Overnight, the battery recharges from the spare capacity of the connection.

From liability to asset – the new economics of fleet charging

This is how a building supports more charging bays on the same contracted connection. At Pluq, this coordination is done by software we call the Pluq Brain. It uses the contracted grid capacity as the limit, follows the building’s demand as it changes through the day and decides how much power each asset releases and each vehicle receives, so that vehicles parked for several hours share the available capacity. For the owner, this means the building can keep pace with rising energy demand even if the connection stays the same. It does not remove the need to check whether hardware, metering and interfaces are fit for the long term, but it shifts a substantial part of the value from the hardware to the control layer.

Four questions for portfolio managers

Whoever is responsible for a portfolio does not have to programme load management or calculate structural loads. But they do need to know what possibilities and limits the technology creates for their properties. Four questions therefore belong on their desk. What capacity is physically, contractually and temporally available in each asset? What charging demand will the asset have to meet in five years? Who is responsible for control and further development over the term of the contract? And what data, continuity and exit rights does the contract secure?

Solar Investors Guide – Energy for cars and trucks

The last question is far from a formality. In October, two real estate lawyers writing in a British professional journal for surveyors described operator agreements with terms of up to around 25 years. Where a substation is added, rights of use lasting 99 years or more may be requested. The continuity of software and operation also has to be secured, in case a provider ceases trading or shuts down its backend. The market has seen such cases in recent years. A contract for charging infrastructure and power management is above all a contract about stability, and about a partner who will still be there.

Whether a building is well located is settled before the foundation stone is laid. Its power is allocated anew every day. Whoever is responsible for the portfolio should know whose hands that allocation is in, and for how long it stays there. The third word in the industry’s oldest line is now power. (Tom de Kort/hcn)

Subscribe to the newsletter

Newsletter subscribers can read this article free of charge.

Subscribe to the pv Europe newsletter